
- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
C/69
Alarm
code
Description What to do
35
Load cell A:
Thermal calibration not present error
Contact the after-sales technical assistance
36
Load cell A:
Check error on LIN bus message
Contact the after-sales technical assistance
37
Load cell A:
CRC error of transmitted data
Contact the after-sales technical assistance
38
Load cell A:
LIN bus message receipt error
Contact the after-sales technical assistance
39
Load cell A:
LIN bus message control hour meter error
Contact the after-sales technical assistance
41
Load cell B:
CRC error of the internal parameters of the load sensor
Contact the after-sales technical assistance
42
Load cell B:
Out of scale signal reading error (10-990)
Contact the after-sales technical assistance
43
Load cell B:
Out of scale internal offset reading error (526-586)
Contact the after-sales technical assistance
44
Load cell B:
Internal 5Vdc power supply voltage error
Contact the after-sales technical assistance
45
Load cell B:
Thermal calibration not present error
Contact the after-sales technical assistance
46
Load cell B:
Check error on LIN bus message
Contact the after-sales technical assistance
47
Load cell B:
CRC error of transmitted data
Contact the after-sales technical assistance
48
Load cell B:
LIN bus message receipt error
Contact the after-sales technical assistance
49
Load cell B:
LIN bus message control hour meter error
Contact the after-sales technical assistance
51 Difference too high between load cell A and B reading Perform calibration test
52
Difference too high between load percentages detected
from channel 1 and 2
Perform calibration test
61
Double safety input congruency error for ground stabilisers
reading.
Contact the after-sales technical assistance
62
Double safety input congruency error for closed
boom reading.
Contact the after-sales technical assistance
63 Inputs congruency error from mode selector Contact the after-sales technical assistance
64 Exclusion key input active upon start-up error Contact the after-sales technical assistance
65 movements re-arm input in active block upon start-up error. Contact the after-sales technical assistance
66 Feedback in frequency signal reading error Contact the after-sales technical assistance
67 Feedback signal reading error of external actuator 1 Contact the after-sales technical assistance
68 Feedback signal reading error of external actuator 2 Contact the after-sales technical assistance
71 Analogical signal reading error from out of scale joystick Contact the after-sales technical assistance
72
Pressure transducer reading error for re-arm verification
with joystick
Contact the after-sales technical assistance
73 CAN BUS messages receipt from optional external unit error Contact the after-sales technical assistance
81 Buttons pressed upon switch-on error Contact the after-sales technical assistance
Comentários a estes Manuais